Analysis of corrected Cerenkov emission during electron radiotherapy by Monte Carlo method
Li, Yi1,2,3; Liu, Hongjun3,4; Huang, Nan3; Wang, Zhaolu3; Zhang, Chunmin2
刊名Applied Radiation and Isotopes
2021-02
卷号168
关键词Corrected cerenkov emission Analysis Electron radiotherapy Monte Carlo
ISSN号09698043;18729800
DOI10.1016/j.apradiso.2020.109481
产权排序1
英文摘要

Cerenkov emission during electron radiotherapy had been emerging as a new dose assessment approach for clinical radiotherapy and could be imaged through a standard commercial camera. The purpose of this work aimed to study the accuracy of corrected Cerenkov emission method during electron radiotherapy by Monte Carlo (MC) method. GAMOS MC software was used to model the physics of electron therapy and calculated dose and Cerenkov photon distribution in water phantom. Compared to ionization chamber and diode measurement, MC simulated dose discrepancy was less than 1% in percentage depth dose (PDD) curves and less than. 2% in crossline profile curves, which was acceptable for clinical criterion. Compared to ionization chamber dose measurement, MC simulated Cerenkov discrepancy was less than 2% in crossline profile distribution, which was acceptable for clinical criterion. However, the Cerenkov PDD curves tended to overestimate the dose at the build-up region and underestimate the dose at the remaining attenuation region. After increasing the Cerenkov distribution depth to 2–3 mm, the discrepancy became well within 1% at the remaining attenuation region, which was acceptable for clinical criterion. Therefore, corrected Cerenkov emission could be used to assess PDD accuracy and crossline profile accuracy during electron radiotherapy. © 2020 Elsevier Ltd

语种英语
出版者Elsevier Ltd
WOS记录号WOS:000605532900026
内容类型期刊论文
源URL[http://ir.opt.ac.cn/handle/181661/93771]  
专题西安光学精密机械研究所_瞬态光学技术国家重点实验室
通讯作者Liu, Hongjun; Zhang, Chunmin
作者单位1.University of Chinese Academy of Science, Beijing; 100084, China
2.School of Physics, Xi'an Jiaotong University, Xi'an; 710049, China;
3.State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an; 710119, China;
4.Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan; 030006, China;
推荐引用方式
GB/T 7714
Li, Yi,Liu, Hongjun,Huang, Nan,et al. Analysis of corrected Cerenkov emission during electron radiotherapy by Monte Carlo method[J]. Applied Radiation and Isotopes,2021,168.
APA Li, Yi,Liu, Hongjun,Huang, Nan,Wang, Zhaolu,&Zhang, Chunmin.(2021).Analysis of corrected Cerenkov emission during electron radiotherapy by Monte Carlo method.Applied Radiation and Isotopes,168.
MLA Li, Yi,et al."Analysis of corrected Cerenkov emission during electron radiotherapy by Monte Carlo method".Applied Radiation and Isotopes 168(2021).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace