Optimization of the POlarimeter-INTerferometer diagnostics system on EAST
Wang, Y. F.4,5; Liu, H. Q.5; Jie, Y. X.5; Lian, H.3; Chu, Y. Q.4,5; Li, W. M.5; Wang, S. X.5; Zhu, X.1,2
刊名JOURNAL OF INSTRUMENTATION
2020-06-01
卷号15
关键词Plasma diagnostics - interferometry, spectroscopy and imaging Nuclear instruments and methods for hot plasma diagnostics
ISSN号1748-0221
DOI10.1088/1748-0221/15/06/T06009
通讯作者Liu, H. Q.(hqliu@ipp.ac.cn)
英文摘要A double-pass, radial-view, 11-chord POlarimeter-INTerferometer (POINT) system has been routinely operated on the Experimental Advanced Superconducting Tokamak (EAST) to provide electron density and current density information for physics research. Stray light occurs due to spurious reflections from optical elements, including lenses, waveplates, windows, and even detectors, along the optical path and can seriously deteriorate the accuracy of the Faraday rotation measurements. As a result of stray light contamination, periodic oscillations can be observed in the Faraday rotation data during the density ramp-up phase. Aiming to realize real-time current profile feedback control using Faraday effect measurements, the contamination from stray light must be removed. Some optimization methods have been explored to decrease the error induced by stray light. The results show that the Faraday angle oscillation during the density ramp-up phase is reduced from 3 degrees-5 degrees to 0.5 degrees-1 degrees (double-pass). Measurement of the noncollinearity error is also performed for the POINT system on EAST. This optimization allows for more accurate current profile measurements for physics research.
资助项目National Key R&D Program of China[2017YFE0300500] ; Users with Excellence Project of Hefei Science Center, CAS[2018HSC-UE007] ; Key Program of Research and Development of Hefei Science Center, CAS[2019HSC-KPRD001] ; National Nature Science Foundation of China[61627901] ; National Nature Science Foundation of China[6162790105]
WOS关键词FAR-INFRARED POLARIMETER
WOS研究方向Instruments & Instrumentation
语种英语
出版者IOP PUBLISHING LTD
WOS记录号WOS:000545351200002
资助机构National Key R&D Program of China ; Users with Excellence Project of Hefei Science Center, CAS ; Key Program of Research and Development of Hefei Science Center, CAS ; National Nature Science Foundation of China
内容类型期刊论文
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/71096]  
专题中国科学院合肥物质科学研究院
通讯作者Liu, H. Q.
作者单位1.Shenzhen Univ, Key Lab Optoelect Devices & Syst, Minist Educ & Guangdong Prov, Coll Optoelect Engn, Shenzhen 518060, Peoples R China
2.Shenzhen Univ, Adv Energy Res Ctr, Shenzhen 518060, Peoples R China
3.Univ Calif Los Angeles, Los Angeles, CA 90095 USA
4.Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
5.Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
推荐引用方式
GB/T 7714
Wang, Y. F.,Liu, H. Q.,Jie, Y. X.,et al. Optimization of the POlarimeter-INTerferometer diagnostics system on EAST[J]. JOURNAL OF INSTRUMENTATION,2020,15.
APA Wang, Y. F..,Liu, H. Q..,Jie, Y. X..,Lian, H..,Chu, Y. Q..,...&Zhu, X..(2020).Optimization of the POlarimeter-INTerferometer diagnostics system on EAST.JOURNAL OF INSTRUMENTATION,15.