Implementation of an FPGA controller for correction power supplies in heavy ion synchrotron | |
Li, Peng2; Yuan, Youjin2; Zhou, Zhongzu2; Wu, Fengjun1,2; Yan, Huaihai2; Cui, Yuan1,2; Li, Min1,2; Huang, Yuzhen2; Zhang, Huajian1,2; Mao, Ruishi2 | |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT |
2015-03-21 | |
卷号 | 777页码:167-171 |
关键词 | Cancer Therapy Orbit Correction Timing System Synchronization Control Waveform Control |
ISSN号 | 0168-9002 |
DOI | 10.1016/j.nima.2014.12.115 |
文献子类 | Article |
英文摘要 | An orbit correction system is utilized to ensure the excellent beam quality of a synchrotron. As the core components of the orbit correction system, correction power supplies play an important role in correcting orbit. To establish the orbit correction system for a dedicated heavy-ion treatment facilities, we developed some new features and integrated them into the controller for the correction power supplies. Especially, the features focused on the reliability of long-time running and on real-time response to the correction data and trigger events. After the features were verified on a correction power supply, the result showed that the correction power supply could meet the needs of the orbit correction system completely. Furthermore, the results of this study may serve to establish and further research the orbit correction system of heavy-ion synchrotron. (C) 2015 Elsevier B.V. All rights reserved. |
WOS关键词 | HIRFL-CSR ; FACILITY ; LANZHOU |
WOS研究方向 | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics |
语种 | 英语 |
出版者 | ELSEVIER SCIENCE BV |
WOS记录号 | WOS:000349468800024 |
内容类型 | 期刊论文 |
源URL | [http://119.78.100.186/handle/113462/50071] |
专题 | 近代物理研究所_电源室 |
通讯作者 | Zhao, Jiang |
作者单位 | 1.Univ Chinese Acad Sci, Beijing 100049, Peoples R China 2.Inst Modern Phys, Lanzhou 730000, Peoples R China |
推荐引用方式 GB/T 7714 | Li, Peng,Yuan, Youjin,Zhou, Zhongzu,et al. Implementation of an FPGA controller for correction power supplies in heavy ion synchrotron[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2015,777:167-171. |
APA | Li, Peng.,Yuan, Youjin.,Zhou, Zhongzu.,Wu, Fengjun.,Yan, Huaihai.,...&Zhao, Jiang.(2015).Implementation of an FPGA controller for correction power supplies in heavy ion synchrotron.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,777,167-171. |
MLA | Li, Peng,et al."Implementation of an FPGA controller for correction power supplies in heavy ion synchrotron".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 777(2015):167-171. |